Nozzle clogged; nozzle severely worn and causing material leakage.
Click to JumpIR3V2 Nozzle replacement Guide
- Heat the nozzle to 200℃ and then unscrew the nozzle using a socket wrench.


- Insert the new nozzle into the socket wrench, align it with the heating block threads and tighten it.